{"id":368,"date":"2022-08-12T18:43:49","date_gmt":"2022-08-12T18:43:49","guid":{"rendered":"https:\/\/www.frioar.com.ar\/munters\/?p=368"},"modified":"2022-08-24T16:31:50","modified_gmt":"2022-08-24T16:31:50","slug":"the-significance-of-humidity-controlin-gmp-compliant-production","status":"publish","type":"post","link":"https:\/\/www.frioar.com.ar\/munters\/the-significance-of-humidity-controlin-gmp-compliant-production\/","title":{"rendered":"The Significance of Humidity Control<br>in GMP Compliant Production"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Many phenomena are influenced by the relative humidity level, and they can cause production processes to be less efficient, less predictable, and more prone to producing products that don\u2019t meet specification.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GMP compliance in pharmaceutical manufacturing requires that any process, person, environment, or equipment with direct impact on the quality and safety of the product being produced must operate within specified limits.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These specified limits should be under the direct control of the manufacturing team, with countermeasures available in the event of a problem. In addition, any other part of the production or storage processes that have an indirect impact must also be assessed for possible risk impact.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Humidity may not seem like an obvious cause of problems, or something that could even result in production being non-compliant, but this can and does occur. Just because one does not see an issue doesn\u2019t mean there isn\u2019t a problem. Many phenomena are influenced by the relative humidity level, and they can cause production processes to be less efficient, less predictable, and more prone to producing products that don\u2019t meet specification.<br><br>Some common issues that can arise from poor humidity control are:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 Increased energy consumption<br>\u2022 Altered aesthetic presentation<br>\u2022 Microbiological growth<br>\u2022 Chemical reactions<br>\u2022 Poor test equipment accuracy<br>\u2022 Moisture regain<br>\u2022 Changes in electrical conductivity<br>\u2022 Effects on operators<br>\u2022 Degradation of buildings and products<br>\u2022 Condensation<br>\u2022 Product drying issues<br>\u2022 Corrosion<br>\u2022 Reduced refrigeration plant efficiency<br>\u2022 Reduced productivity<br>\u2022 Ice build up<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 1 shows the influence on storage of a variety of materials as relative humidity changes. Storage in this sense is not just restricted to<br>warehousing, but also applies to any material, object, or equipment that remains stationary in a fixed location for extended periods. So, think of this also in the context of equipment and fittings within a pharmaceutical manufacturing plant.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"312\" height=\"201\" src=\"https:\/\/www.frioar.com.ar\/munters\/wp-content\/uploads\/2022\/08\/munters-significance-of-humidity-control-in-gmp-compliant-production-4.jpg\" alt=\"\" class=\"wp-image-374\" srcset=\"https:\/\/www.frioar.com.ar\/munters\/wp-content\/uploads\/2022\/08\/munters-significance-of-humidity-control-in-gmp-compliant-production-4.jpg 312w, https:\/\/www.frioar.com.ar\/munters\/wp-content\/uploads\/2022\/08\/munters-significance-of-humidity-control-in-gmp-compliant-production-4-300x193.jpg 300w\" sizes=\"(max-width: 312px) 100vw, 312px\" \/><figcaption>Figure 1: Effect of RH% on materials in static locations.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">It is important to note the relationship between relative humidity (RH%) and air temperature, as variations in temperature also will affect the<br>RH%. For example, a sufficiently large drop in air temperature can result in water vapor condensing out. Alternatively, cold surfaces will cause condensation to form if the surface temperature drops below the dew point of the air around it.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-vivid-cyan-blue-background-color has-background\" href=\"https:\/\/www.frioar.com.ar\/munters\/wp-content\/uploads\/2022\/08\/munters-significance-of-humidity-control-in-gmp-compliant-production.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">ver articulo completo<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Many phenomena are influenced by the relative humidity level, and they can cause production processes to be less efficient, less predictable, and more prone to producing products that don\u2019t meet specification. GMP compliance in pharmaceutical manufacturing requires that any process, person, environment, or equipment with direct impact on the quality and safety of the product [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":377,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos"],"_links":{"self":[{"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/posts\/368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/comments?post=368"}],"version-history":[{"count":5,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/posts\/368\/revisions"}],"predecessor-version":[{"id":469,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/posts\/368\/revisions\/469"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/media\/377"}],"wp:attachment":[{"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/media?parent=368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/categories?post=368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.frioar.com.ar\/munters\/wp-json\/wp\/v2\/tags?post=368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}